- Specifications:
- Control Inputs:
- ON: Momentary or maintained contact closure
- OFF: Momentary or maintained contact closure
- DC: 5-24V DC, maintained voltage
- Outputs Relays:
- 6 form-C (SPDT), 1A, 24V DC max.
- AC Tally Light: AC Line Voltage, 200W max.
- DC Tally Light: 12V DC, 300mA max/1A current sink Connections:
- Control inputs, relay & DC outputs: euroblocks
- AC Tally Light: Grounded AC receptacle
- Power Input 115 or 230V AC, 50-60Hz, 4W + Tally load Approval City of Los Angeles Elect. Test Lab
- Construction Steel enclosure
- Physical: 5.7”w X 1.7”h X 6.0”d, 3lbs
- Mounting Table top, optional rack mount shelf, optional wall/cabinet mounting brackets