Furman’s Contractor Series MiniPorts extend the benefits of SmartSequencing to electronics outside of the equipment rack, providing tremendous flexibility to any installation scenario. Units may be daisy-chained and fully controlled via a Furman SmartSequencer, legacy Furman sequencer, third-party sequencers, via the Internet (with BB-RS232 adaptor and SmartSequencer), and/or control and automation systems.
DIP switches and potentiometer allows customization of settings such as sequencing delays, 12V on/off, and more. Security covers are provided to prevent unauthorized personnel from tampering with DIP switches.
Sequencing of duplex initiated remotely by standard analog triggering (remote terminal) or data link (SmartSequencing from CN-1800S or CN-2400S).
The CN-20MP can shut itself off automatically when triggered by a fire alarm.
Specifications
• AC Voltage Input Range 90-139VAC, 50/60Hz
• Maximum AC Current Rating 20 Amps (No Breaker)
• AC Cord 3/12AWG, 10 feet, black, fixed, NEMA 5-20P plug
• AC Receptacles 2 NEMA 5-20R’s (1 duplex)
• Surge/Under-Overvoltage Protection AC Undervoltage Protection: EVS, 77VAC+/-3VAC AC Overvoltage Protection: EVS, 140VAC+/-5VAC AC Overvoltage Reset Modes: Enabled and disabled (configurable via DIP Switch #9)
• Operating Temperature Range 5C (40F) to 40C (105F) degrees
• Humidity Range <90% rH (Relative Humidity)
• User Interface: Circuit Breaker: No Breaker Front panel diagnostic indicators (LED): Power, Extreme Voltage, Primary Link, Secondary Link Side Panel DIP Switch Features (with security cover): 1 Minute Delay, 2 Minute Delay, 4 Minute Delay, Force Off NO/NC, 12V Mode On/Off GND Mode On, Momentary/Maintained, Primary/Secondary, EVS Reset Auto/Manual Side Panel Potentiometer allows fine tune delay adjustments
• Control/Status/Triggering (Rear Panel): Remote Terminal: +5-30VDC In, 12VDC (12mA) Out SmartSequencing: Phoenix-type 4-Pin Connector, Screw Terminals, Primary & Secondary Links (Current Loop - 1000’ nominal) Remote Terminal: Phoenix-type 5-Pin Connector With Screw Terminals; +12V, STAT, REM, GND, DLY_OUT (Class 1 Wiring) Force Off: Phoenix-type 2-Pin Connector With Screw Terminals, FORCE OFF (Class 1 Wiring) RS-232 Compatible: Yes, indirectly, when connected via SmartSequencing to a Furman Smart Sequencer with an RS-232 port IP Accessibility: Optional IP control via Telnet, HTTP, or BlueBOLT® when used in conjunction with SmartSequencing Voltmeter: Available with SmartSequencing Ethernet option, ± 2VAC accuracy Ammeter: Available with SmartSequencing Ethernet option, ±1A accuracy
• Power Consumption (No Load): 10 Watts
• Safety Agency: CSA, RoHS Compliant