- Main features:
- Add Contacts to Any Control Signal
- Activation from Logic Circuits
- DPDT Switching Relay
- Open-Collector Switching
- Control from Switch, Button or Logic Circuits
- Specifications:
- Control Inputs:SLAVE terminal used as an input from remote push-button or switch turns on relay when that switch is on. Activation is by connecting this input to Ground. Input from other equipment's open-collector output turns relay on when open-collector is on.
- Note: RDL switching STICK-ONs have open-collector outputs suitable for driving an ST-LCR1. 5V+ accepts 3.5 to 12 Vdc to turn on relay. Relay is on only when this control signal is applied. 24V+ accepts 12 to 35 Vdc to turn on relay. Relay is on only when this control signal is applied.
- Control Output:SLAVE terminal open-collector @ 25 mA suitable to drive indicators or slave LCRs
- Switching Contacts:Double-pole, double-throw
- Maximum Switching Power: 60 W (220 Vdc, 125 Vac, 2 A)
- Power Requirement:GROUND-REFERENCED, 24 Vdc @ 50 mA * * Assumes 20 mA max load at SLAVE output
- Ambient Operating Environment:-10° C to 55° C