The Juice Goose CQ-2200, along with the other products in the CQ Series, provide a versatile and powerful means of remotely activating AC power in a sequenced array for application to both sensitive and high amperage equipment. CQ Series products need no additional controllers. Each contains the circuitry to be activated by a simple contact closure and to perform in coordination with other CQ devices. All power down sequences are exact reversals of the power up sequences.
The CQ-2200 features two duplex receptacles, each with its own preset turn on and off timing. When used to power amplifiers each of the CQ-2200’s sequence events will be triggered after a previous CQ device has completed its sequenced turn on. Because the CQ- 2200 activates its outlets in two stages it is useful as a stand-alone sequencer, being triggered by a contact closure or a Juice Goose RC-5 key switch. It can also increase the number of amplifiers powered on a single circuit without risk of inrush tripping a circuit breaker.
All CQ products can be easily controlled by way of either 8 wire, RJ-45 or 6 wire, RJ-12 cable. Each CQ has a Sequence Signal Input and Output connector on the chassis. This communication link allows any CQ device to be installed at any stage in a power sequencing system and act as a power sequencer or controller. There is no limit to the number of CQ devices that can be connected in this manner. Because the sequence process is controlled with a latching contact closure the system can be activated with a custom mounted single pole switch, a relay, the control switch on the CQ device itself or a Juice Goose RC-5 key switch control accessory. It can also be activated with controllers from Crestron, AMX and other manufacturers.
The CQ-2000 and 2200 feature a three position switch on the front of the chassis. This switch is active only if there is no control cable on the Sequence Signal Input connector. When active, this switch allows the unit to sequence up or sequence down and to control the sequencing of any unit connected to the Sequence Signal Output connector. The Manual On switch position allows the CQ-2000 or 2200 to be manually operated, overriding the control circuit in the unlikely event of a fault or failure. Lights on the front of the chassis allow monitoring of the unit operation. The PROCESSOR light will blink to indicate the control processor on the unit is functioning. The POD lights are illuminated as a result of contact closure by the CQ relays, indicating that actual relay closure has occurred.